SKL-WP2 Penetrant
Description
Product information
Magnaflux SKL-WP2 Water Washable Visible Penetrant
Developed for large surface areas and rough surfaces where excess penetrant is difficult to remove with a solvent removable cleaner or emulsifier, SKL-WP2 is a water-removable dye penetrant for Type 2 penetrant testing in visible white light.
This bright red penetrant is designed to wash off parts with ease, leaving less background for clearer indications – even on rough surfaces. The quick rinsing reduces water usage in the inspection process for a reliable NDT process with less cost per part.
This colour-contrast penetrant meets all NDT specifics for dye penetrant testing and can be used on a wide variety of metals, including non-ferrous and ferrous. It is normally used on welds, forgings, pressure vessels, castings and general metal work, and it lends itself to a production environment where many parts are inspected daily
Benefits
Dependable and convenient to use
- Easy to carry and use in the field with the convenient aerosol cans which are carefully designed for consistent, even coverage and maximum test area coverage
- Use in all conditions without the need for darkness or UV lights
- Quickly and completely covers the entire test surface due to high surface wetting
Maximum indication detection
- Produces strong, vibrant indications thanks to the bright, vibrant red colour, especially when used with SKD-S2 solvent-based developer
Wide application versatility
- Inspect a wide range of components without fear of corrosion or specification non-conformance
- Meets AMS 2644 and is NDT-approved for professional industrial applications
- Reduced processing cost per part due to excellent wash-ability, which is especially useful for large parts and cast components
Maximize operator comfort and safety
- Promotes better inspection quality by providing the operator with a more comfortable work environment
- Reduces discomfort from strong odours
- Exceeds all EHS requirements, does not contain NPEs or phthalates
Features
- Easy, water-wash removal
- ISO 3452 sensitivity level #2
- Can be used with Method A or Method C
- Vivid, high-contrast red colour
- Superior flaw resolution
- Good surface wetting
- Optimized capillary action
- Works in visible light
- Very low toxicity
- Low odour
- NDT-spec compliant
Specification compliance
- AECL
- AMS 2644
- ASME BPVC
- ASTM E1417
- ASTM E165
- Boeing BAC 5423 PSD 6-46 or 8-4
- Boeing PS-21202
- GE P50YP107
- ISO 3452
- MIL-STD-2132
- MIL-STD-271
- NAVSEA T9074-AS-GIB-010/271
- QPL SAE AMS 2644
Applications
Defect location: open to surface
SKL-WP2 is ideal for:
- A production environment where many parts are inspected daily.
- Castings
- Forgings
- Welds
- Pressure vessels
- Tubular goods
- General metal work
Defect examples: cracks and leaks
NOTE: we do not recommend SKL-WP2 for inspecting plastic materials, as it may stain, soften or even dissolve the base material under test.
Instructions for use
Ensure test part is clean and dry, and free from oil, grease and other contaminants.
Apply SKL-WP2 penetrant by immersion dip, brush, flow on, conventional or electrostatic spray. Cover the test area completely.
Allow penetration time. Minimum penetration time is 2 to 5 minutes, with 10 minutes being adequate for most situations. Lower temperatures thicken the penetrant and require longer penetration times.
Spray the component with clean water at 10°C to 40°C, or wipe with a lint-free cloth dampened with our SKC-S cleaner. Once clean, the component should be dried before a developer is applied.
Apply a thin layer of developer* to the surface and allow a minimum of 10 minutes development time before inspecting the component under white light. Indications will appear dark red against the white developer background.
* A developer is used to maximise sensitivity and provide a white contrasting background. Two types of developer can be used:
- Solvent-based: quick-drying materials which are applied by spraying. The component under test must be dry before developer is applied.
- Water-based (aqueous): can be applied by dipping or spraying. To maximise penetrant sensitivity, parts should only be exposed to aqueous developers for short periods of time. The component must be dried before inspection.
Developer residue can be removed either by wiping with a cloth or by a water and detergent wash. SKL-WP2 Penetrant residues can be removed by vapour degreasing or solvent soak.