+44 (0) 1429 836655 [email protected]

Echograph 1095 • Fidgeon

Products > >

Request Account

Echograph 1095

Clear
SKU: N/A Categories: ,

Description

The Echograph 1095 features time corrected gain and backwall echo attenuation.

Designed as an ideal instrument for manual ultrasonic testing, it is equipped with the advantages of digital test equipment: Sturdy mechanical and electronic components with a large, high-contrast screen and a convenient, practical user interface make it nearly indestructible even in harsh operating environments or outdoors.

Main features:

The powerful ultrasonic flaw detector features 3 monitors for amplitude and time-of-flight measurement and 3 associated status lamps on the front panel for monitoring of threshold levels. The very compact instrument (54 mm case depth) provides fast digital ultrasonic electronics with a high sampling rate and pulse repetition frequencies up to 5000 Hz.

Operating assistance for less-experienced users

A convenient user guidance supports less-trained UT inspectors, also during probe handling and instrument adjustment: Simply activate the wizard and follow the instructions on the screen. Even difficult evaluation procedures for defect sizing (DAC/TCG, JIS, AWS or DGS) are set almost automatically.

Display Evaluation with DGS and DAC

Display evaluation DGS method (option):

  • Not restricted to special probes (DGS curve is calculated within the instrument)
  • Visualisation of the reference DGS curve
  • Defect size (FBH = flat bottom hole) is directly shown
  • DGS with KARL DEUTSCH TR probes
  • Indication of up to 6 additional threshold curves

Display evaluation DAC method (option):

  • Reference line method (EN 1330-4)
  • Optical and acoustical alarm when exceeding or dropping below the curve
  • Indication of up to 6 threshold curves
  • DAC support points can be manually added, shifted and deleted (up to 16 points)
  • Calculation of time corrected gain from the DAC curve

Time Corrective Gain TCG

For TCG evaluation the gain is adjusted depth-dependent according to the previously recorded DAC curve (option).

As a result, large reflectors with equal sizes are displayed with equal amplitudes though they are located in different depths.

Backwall Echo Attenuation

Very often the flaw echoes between transmitter pulse and backwall echo are much smaller than a backwall echo used for monitoring of coupling. With activated backwall echo attenuation monitor 3 can be shifted over the backwall echo and a separate gain can be selected there. As a result, it is possible to show all interesting echoes in a useful height (in the example picture: amplification 28 dB within and 45 dB outside of monitor 3.

The high-precision distance measurement is executed with the aid of signal zero crossings and uses the RF-mode of the unit. Exclusively considering zero crossings minimizes influences of amplification and signal shape, thus wall thickness values are highly accurate and stable. Besides arithmetic averaging, storing of minimal and maximal values is available. As a result, the unit is optimized e.g. for the measurement of corrosion.

Key Advantages:

  • Housing dimensions: 149mm×262mm×54mm with protective rubber holster for high impact resistance
  • Large 7″ colour TFT display with screen resolution of 800×480 pixels
  • Weight incl. Li-Ion battery and protective rubber holster: 2Kg
  • Clearly structured operation menu with freely selectable languages
  • 6 function keys below the display are freely programmable by operator
  • DGS flaw size evaluation, DGS curve is shown on the screen
  • DAC/TCG depth compensation curves displayed on the screen
  • Up to 4 additional DAC/TCG curves resp. DGS curves can be shown on the screen, each curve individually shifted relative to the screen, each curve individually shifted relative to initial curve by max +15dB
  • Evaluation according to AWS D1.1/1.1M standard as well as JIS Z 3060
  • Probe database for easy entering and editing data even for any kind of probe
  • User guided assist menus for screen setup, probe evaluation and sound velocity measurement (2 point adjustment)
  • Monitoring of echo amplitudes and signal travel times by three independent flaw gates
  • Echo to echo evaluation between 2 gates (M1 and M2)
  • Gate 2 tracking in relation to gate 1
  • Back wall echo attenuation by individually adjustable amplication for gate 3
  • Precise wall thickness measurement by zero point edge evaluation
  • Additional LED indications for monitoring the gate thresholds M1, M2 and M3
  • User defined measurement selection: up to 6 freely selectable measuring data can be shown on the display in well readable large digits
  • Echo amplitude selectable in percent screen height, mm FBH or dBrel
  • Evaluation in amplitude and mm sound path, mm depth and mm (reduced) projection distance
  • Echo display: half-wave positive, half wave negative, full wave, RF display
  • A-Scan representation as standard image (envelope), inverse (filled), freeze or with echo-dynamic curve
  • Zoom function for gate 1 and gate 2
  • Adjustable gain up to 110dB
  • Switchable between tunable square wave pulse and broadband spike pulse
  • Automatic pulse width adjustment based on probe data between 30ns – 5μs (corresponding to 100kHz – 17 MHz probes)
  • Pulse repetition frequency from 10Hz up to 1KHz for square wave poulse and up to 5KHz for spike pulse
  • Comfortable text editor enables the storage of each perameter set by a special name
  • 50,000 configurations can be stored, up to 500 configurations are displayed
  • Sound velocity adjustable between 200m/s up to 15,000m/s in steps of 1m/s
  • Battery operation approx. 9 hours in standard setup
  • Outputs:
    1. 8GB SD card (2…32 GB)
    2. Standard VGA output
    3. USB interface
    4. 3 gate (alarm) outputs (TTL level)
    5. 2×Lemo 1 probe lead connectors
    6. Protection class IP64

 

 Additional Information

Product number F20.0100

Additional Accessories

Link to probes page

Ultrasonic couplant

Probe leads

Related products

Available Models

Echograph 1095 Basic

Echograph 1095 DAC/TCG/AWS

Echograph 1095 AVG/DAC/TCG

Echograph 1095 AVG/DAC/TCG/AWS/JIS

Further Echograph 1095 options on request

Matrix Memory

TOFD

B-Scan

Text on the button

Request a free quote today for an ECHOGRAPH 1095.

Additional information

Option

, , ,

Questions? Ask our specialist team for NDT help or advice