Y6 Electromagnetic Yoke
Description
Product information
The Y6 is a durable, lightweight AC magnetic yoke designed for reliable, one-person detection of surface and sub-surface indications. Featuring sealed chemical-resistant construction, articulating legs to contour to any part shape and robust strain-relieved power cord for field use, the Y6 is ideal for inspection of welds and other remote testing.
Main features:
- Sealed, durable construction
- Chemical and abrasion resistant
- Exceeds ASTM lifting specifications
- Individual serial number on each yoke
- Articulated, double-jointed legs
- Demagnetising capability
Specification compliance
- ASME Boiler and Pressure Vessel Code Section V, Article 7
- ASTM E709
- ASTM E1444
- EN-ISO 9934-3
- MIL-STD-271
All Y6 yokes carry the CE mark and conform to the appropriate European Union directives.
Key Advantages:
Applications
Defect location: Surface and sub surface Ideal for:
- Field testing
- Difficult to reach areas
- Spot inspections
- In-service inspections
- Weld inspection
Defect examples:
- Seams
- Tears
- Shrink cracks
- Grinding cracks
- Quenching cracks
- Fatigue cracks
Product properties
| Weight: | 3.4Kg |
| Leg Span: | 25 – 250mm |
| Cord Length: | 3.7m |
| Duty Cycle: | 23%, max on time is 30 seconds |
| Method of current control and effect on waveform: | Sinusoidal AC mains or DC battery |
| Duty Cycle at maximum output
(ratio of current ‘ON’ to ‘Total’ time |
23% |
| Maximum current ‘ON’ time | 30 seconds |
| Recommended pole spacing
(maximum and minimum pole spacing) |
Smin 35mm
Smax 140mm |
| Cross sectional dimensions of the poles | 25×25mm |
| Pole spacing
(AC tangential field strength in kA/m at the central point between the poles on a 500×200×10mm Steel plate) |
35mm: 12kA/m
140mm: 2kA/m 250mm: 1.4kA/m |
| Overall dimensions | 220×155×50mm |
| Specified electrical protection | IP 64 |
| Minimum requirements of EN-ISO 9934-3(E): | |
| Duty Cycle >10% | Exceeds |
| Current ON time > 5 seconds | Exceed |
| Surface temperature of handle >40°C | Complies |
| Tangential field strength at Smax > 2kA/m (rms) | Exceeds |
| Lifting force > 44 N | Complies |
| AC Voltage | 110v | 230v |
| DC Voltage | 12v | 12v |
| Frequency | 50Hz | 50Hz |
| Supplied current in air – AC | 3.5A | 2.3A |
| Supplied current in air – DC | 8.5A | 2.5A |
| Weight lifted at 140mm pole spacing | AC: 10.5Kg
DC: 32Kg |
AC: 10.5Kg
DC: 32Kg |